Site Manager Parameters
117376-C Rev. 00
A-19
Parameter: T303, Setup Message Timer
Path: Configuration Manager > Protocols > Frame Relay > Interfaces > Signaling
Default: 4
Options: 2 to 90 seconds
Function: Indicates the number of seconds allowed from the time the router sends a setup
message to the called subscriber and receives a connect or call proceeding
message from the called subscriber.
In the event of a timeout, the router retransmits the setup message and restarts
the timer. If the timer expires a second time, the call is cleared.
Instructions: Enter the timer value for call setup.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.9.1.6
Parameter: T305, Disconnect Timer
Path: Configuration Manager > Protocols > Frame Relay > Interfaces > Signaling
Default: 30
Options: 20 to 90 seconds
Function: Indicates the number of seconds allowed from the time the router sends a
disconnect message and receives a release message back. This timer is used
when this router initiates call clearing.
In the event of a timeout, the router sends a release message and enters the
release request state. The timer is not restarted.
Instructions: Enter the timer value for call clearing.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.9.1.7