Configuring Dial Services
9-26
117353-B Rev. 00
Using the BCC
To enable or disable the factory default settings for the modem configuration,
navigate to the modem prompt and enter the following:
factory-defaults-load
<
enabled/disabled
>
For example:
modem/2/1# factory-defaults-load enabled
Using Site Manager
To enable or disable the factory default settings for the modem configuration:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the COM connector whose
configuration you want to change.
The connector name should have a D, B,
or W next to it.
The Edit Connector window opens.
2. Click on
Edit Modem
. The V.34 Modem Interface Parameters
window opens.
3. Set the
Modem Factory Defaults
parameter. Click on
Help
or see the
parameter description on page A-16.
4. Click on
OK
. You return to the Edit Connector window.
5. Click on
Done
. You return to the Configuration Manager
window.