An IP500 Legacy Carrier card can be used to fit IP400 trunk or VCM cards into an IP500 or IP500 V2 control unit. Up to 2
IP500 legacy carrier cards can be inserted.
Warnings
1.Correct anti-static protection steps should be taken while handling
circuit boards.
Parts and Equipment Required
1.o IP500 Carrier Card
2.o IP400 Card
The table opposite lists supported cards. Any card not listed is not
supported. Cards are supplied with 2 plastic stand off pillars.
Trunk cards are also supplied with a replacement blanking plate
which is not required.
Tools Required
1.o 5mm Flat-blade screwdriver.
2.o Anti-static wrist strap and ground point.
Procedure: Installing a Carrier Card
1.Check that correct cards have been supplied.
2.Ensure that you are wearing an anti-static wrist strap connected
to a suitable ground point.
3.On the carrier card identify the position of the jumper block and
stand off pillar holes for the IP400 card. The peg holes are labeled
as VCM or TRUNK.
4.If fitting an IP400 trunk card, identify which of the plastic snap-off
panels on the front of the carrier card need to be removed to
allow the trunk cable connections. Carefully remove those panels.
5.Fit the stand off pillars to the IP500 carrier card.
6.Using minimal force and checking that the pins are correctly
located, push the IP400 card onto its jumper and the stand off
pillars.