Chapter 4 Upgrading to BCM50 2.0 and SRG50 2.0 17
Upgrade Guide
After the keycode is applied to the system, the Applied dialog box appears.
5 Click OK.
Performing the second stage of the upgrade
The second stage of the upgrade contains the BCM50 2.0 software and client applications. This
stage of the upgrade takes approximately 30 to 40 minutes depending on connection speed and the
location of the upgrade files. The system automatically reboots after this stage is complete. If you
are upgrading directly from the CDs, ensure that the first CD (CD1) is in the CD-ROM drive of the
management computer.
To perform the second stage of the upgrade, follow the procedure “Performing the stages of the
upgrade” on page 18. Be sure to select BCM50R1_to_R2_Upgrade_2 in step 6 of the procedure.
Performing the third stage of the upgrade (optional)
The optional third stage of the upgrade includes the voice mail prompt files and documentation. If
you do not require updates to these components, then you do not need to perform this stage of the
upgrade. Or, you can select only the items that you need to update. If you are upgrading directly
from the CDs, ensure that the second CD (CD2) is in the CD-ROM drive of the management
computer.
This stage of the upgrade takes approximately 15 to 30 minutes depending on connection speed,
the components selected, and the location of the upgrade files. Your voice mail system is
unavailable during this stage of the upgrade. The voice mail prompts require a restart of the voice
mail component of the system.
Warning: Do not reboot your BCM50 system at this time, even if you receive a
message asking you to reboot. See the figure below.
Warning: After you start this stage of the upgrade, your system is out of service
until this stage of the upgrade is complete.