117376-B Rev. 00 A-7
Parameter: Polling Interval
Path: Configuration Manager > Protocols > Frame Relay > Interfaces
Default: 10
Options: 5 to 30 seconds
Function: Specifies the interval between status inquiry messages that the router transmits.
Status inquiry messages cause a network response in the form of a link integrity
verification message or full status message. Successful completion of the
request/response “handshake” verifies the status of the router/frame relay
network link.
Instructions: You should accept the default value, 10 seconds. If this value does not match
what the network requests, enter a value that is appropriate for your network in
the range of 5 to 30 seconds. Polling Interval does not function if you set
Mgmnt Type to DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.10
Parameter: Full Enquiry Interval
Path: Configuration Manager > Protocols > Frame Relay > Interfaces
Default: 6
Options: 1 to 255 polling intervals
Function: Specifies the interval between full status inquiry messages that the router
transmits. Full status inquiry messages cause the network to send a full status
report message, which lists all PVCs, the PVC status (active or inactive, and
new or previously established). This parameter works with the Polling Interval
parameter.
The default value, 6, tells the router to send a full status inquiry every 6 polling
intervals. For example, with a polling interval of 10 and a full enquiry interval
of 6, the router transmits a full status inquiry every 60 seconds; with a polling
interval of 20 and a full enquiry interval of 30, the router transmits a full status
inquiry every 10 minutes (600 seconds).
Instructions: Enter a value from 1 to 255, according to what the network dictates. Full
Enquiry Interval does not function if you set Mgmnt Type to DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.11