Customizing PPP
115391-A Rev. A 11-5
You can change as many parameters as necessary before forcing the renegotiation.
After making all your changes to these parameters:
1. Set the Enable (LCP) parameter to Disable and, if necessary, apply the
changes.
2. Reset the Enable (LCP) parameter to Enable and, if necessary, apply the
changes.
Enabling Link Control on a Line
The Link Control Protocol (LCP) is enabled by default on the interface. Disabling
the Enable (LCP) parameter generates a “close” event to the LCP, and enabling
this event generates an “open” event to the LCP. A major use of this sequence is to
force LCP renegotiation on the interface during dynamic reconfiguration. Doing
so means that any changes you have made to the line parameters are included in
the negotiations.
To disable LCP on this interface, set Enable (LCP) parameter to Disable. To
reenable LCP, set this parameter to Enable.
Setting Transmission Parameters
You can specify the timing of transmissions and the threshold for considering the
link to be down using the parameters described in the following sections.
Setting the Restart Timer
The value of the Restart Timer in Seconds parameter specifies the number of
seconds that the restart timer waits before retransmitting data. The default value is
3 seconds, and the range is 1 through 1000 seconds.
Site Manager: Enable (LCP) parameter: page A-82
Site Manager: Restart Timer in Seconds parameter: page A-83