Using the Quad Serial PMC Module
311905-B Rev 00 1-7
For more information about which 44-pin serial cable to use, see “Cabling” on
page A-1.
To connect the serial interface cable to the quad serial interface:
1. Connect the 120-pin portion of the 120-pin to quad 44-pin adapter
(Figure 1-6).
This quad serial adapter cable is required to connect up to four 44-pin cables
to the quad serial PMC modules.
Figure 1-6. Quad Serial PMC Module Cable Connection
2.
Secure the quad serial adapter cable to the interface PMC module using
the captive screws on the cable.
The screws should be tightened completely.
3. Locate the serial interface cables and connect one to each end of the quad
serial adapter cable. Make sure the screws are tightened completely.
The serial interfaces automatically configure the desired electrical interface
when used with standard keyed cables.
4. Arrange the cable in the cable loom.
For instructions, see “Using the Cable Looms to Manage Cables” in Installing
and Operating the Passport 5430 Multiservice Access Switch.
5. Connect the remote end of each cable to the appropriate communications
equipment.