Avaya Managing Routers and BNX Platforms Bedienungsanleitung Seite 230

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 250
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 229
Managing Routers and BNX Platforms
B-16
Parameter: Slot Upper Bound
Default: 0
Range: 0 to 14
Function: Along with the Slot Lower Bound parameter, this parameter specifies the
slot or range of slots on which you want to filter the log messages for this
entity.
Instructions: To specify a range of slots, enter the upper number of the range in this
field. You must specify the lower number of the range in the Slot Lower
Bound field, as described previously.
To filter events for a specific slot, enter the slot number in this field. You
must enter the same number in the Slot Lower Bound field.
If you do not want to use this filter, accept the default, 0. Be sure to do the
same in the Slot Lower Bound field.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.11
Parameter: Fault Map
Default: CRIT
Options: EMERG
| ALERT | CRIT | ERR | WARNING | NOTICE | INFO
| DEBUG
Function: Maps router event messages with a severity level of fault to an error level
that UNIX syslogd recognizes. T
able B-1 describes each of these error
levels.
Instructions: We recommend you accept the default UNIX error level for this severity
level. To map this severity level to a different UNIX error level, click on
Values, and then select the error level you want.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.12