GeoTel Features User Manual TCAD Alarm Messages
P0602482 Ver. 04.03 Avaya Page 451
Troubleshooting Guidelines
TMS Initialization
Failed TMS bootup usually prevents the rest of the system from starting up properly.
To diagnose possible TMS initialization problems:
Verify the bootp file entries. Look for invalid/conflicting MAC and IP
addresses.
Verify that the TMS images are valid and available.
Verify that the NIC (or hub-NIC) is installed properly (seated in the
backplane) and booted properly.
Verify that all cables are connected and secure.
•Use the ping command from a separate system to verify TMS network
connections.
Use a separate console hookup to further investigate the source of the TMS
initialization failure.
TMS PLL
The system uses redundant clocking for TMS-DCC timing, although only one clock is
used as the reference at any given time. A system can function as long as it has at least
one clock source available for primary reference. However, it is preferable to have
both clocks available. To diagnose possible TMS PLL problems:
Verify that the system clocking configuration in tms.cfg is correct for the
installation. This is normally set at the factory and should not be changed.
Verify that the spans which drive the clocking are up and in service.
•Use the ncd systemstatus command to further diagnose the cause of the
PLL problem.
TMS Memory
The system voice memory is used by line resources (fax, player, recorder, etc.). The
system CPU memory is used by normal call processing applications and allocated/
freed during normal system functioning. In some heavy load circumstances, the TMS
may temporarily run out of memory but the system should recover automatically
without adverse effects. Memory problems may also occur when a failure occurs on
another component and the system is in transition to the redundant backup. To
diagnose possible TMS memory problems:
Check to see if any software has been updated (use the perirev command) or
applications have been changed. The new software/application requirements
may exceed the amount of memory currently installed.
Verify that there are no network problems or failure changeover situations. If
the system is in a changeover state, the memory problems should stop after
changeover completes.