Chapter 25: Table: eKERNEL_ALARM
eKERNEL_alarm parameters
ALA_id_n
This field specifies the unique identifier of the alarm. Although you can to enter a numeric value
of choice, Avaya recommends developing a logical naming convention for alarms.
A common approach is to base the numbering scheme upon input program identifier (that in
turn is built upon site and area of the input program and a input program sequence number).
A two-byte sequence number is the appended. This brings the length to seven bytes.
Table 27: Alarm identifiers
Byte 1 Site identifier
Byte 2 Area identifier
Byte 3-5 Input program identifier
Byte 3 1 eCAP or eAPI or eESPA
2 eSNMP
4 eVBVOICE
5 eCSTA
DECT Messenger Installation and Commissioning — Book 2 March 2012 265