Universal Paging Access Module
Installation and Use Manual
© 1999 Bogen Communications, Inc.
All rights reserved. 54-2003-01 9910
LUUPAM: PEC Code: 5335-701
COM Code: 405891698
LUPS: COM Code: 405742735
LUWMT1A: COM Code: 405891680
LUATMC: COM Code: 405891706
Select Code: 701-000-106
Issue 1, October 1999
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - Installation and Use Manual

Universal Paging Access ModuleInstallation and Use Manual© 1999 Bogen Communications, Inc.All rights reserved. 54-2003-01 9910LUUPAM: PEC Code: 5335-

Seite 2

Trunk Port Connections - Loop Start (cont'd)Figure 2: Trunk Port Connection: Loop Start Trunk Port[10]

Seite 3 - Contents

[11]Specific InstructionsTrunk Port Connections - Ground Start NOTE: Controls for VOX DELAY, PAGING TIME, MODE Switch S5 and AUX switchesS1, S2, S3, a

Seite 4

Trunk Port Connections - Ground Start (cont'd)9.Connect UPAM +24/48V terminal to PBX ground.NOTE:Usually the AC GND terminal on the included 48-v

Seite 5 - Product Identification

[13]Specific InstructionsStation Port / Centrex ConnectionsDisconnect Methods In station port operation, the UPAM provides CPC (calling-party-controll

Seite 6 - Components

[14]Station Port / Centrex Connections (cont’d)5. Connect "Tip" of station port to T terminal of UPAM (see Figure 5).6. Connect "Ring&q

Seite 7 - General Instructions

Station Port/Centrex Connections (cont'd)Important Centrex SettingsSome phone systems (in particular, Centrex-type systems) may produce open-swit

Seite 8 - General Instructions (cont’d)

Station Port/Centrex Connections (cont'd)Inhibit Default TimerChanging Default Timer RangeRing DelayAn option is available to inhibit the default

Seite 9

[17]Specific InstructionsTrunk Port Connections - Page Port NOTE: Controls for VOX DELAY, PAGING TIME, MODE Switch S5 and AUX switchesS1, S2, S3, and

Seite 10

Trunk Port Connections - Page Port (cont'd)7.Connect PT and PR terminals and contact closure on UPAM to the paging system,as shown in Section 3.

Seite 11 - Specific Instructions

[19]3. Connection to the Paging SystemGeneral GuidelinesThe UPAM is designed to connect to typical central-amplified and self-amplifiedpaging and soun

Seite 12

© 1999 Bogen Communications, Inc.All Rights Reserved. Printed in U.S.A.NoticeEvery effort was made to ensure that the information inthis guide was com

Seite 13

[20]Connecting the UPAM to an Amplifier's Lo-Z/600-ohm Input (cont’d)1. Make sure that the amplifier is turned off or unplugged. 2. Connect one s

Seite 14

Connecting the UPAM to an Amplifier’s Lo-Z/600-ohm Input (cont'd)Figure 7. Typical Connection to a Lo-Z/600-ohm Input[21]

Seite 15

[22]Typical Installation: Connecting the UPAM to an Amplifier’sHi-Z AUX InputYou can connect the UPAM to an amplifier's Hi-Z input by using the L

Seite 16

Connecting the UPAM to an Amplifier's Hi-Z AUX Input (cont'd)Figure 8. Typical Connection to a Hi-Z Input[23]

Seite 17

[24]Typical Installation: Connecting the UPAM to an Amplifier’sMIC InputDue to the higher sensitivity of Hi-Z microphone inputs, they should be used o

Seite 18

Connecting the UPAM to an Amplifier's MIC Input (cont'd)Figure 9. Typical Connection to a MIC Input[25]

Seite 19 - Lo-Z/600-ohm Input

[26]Typical Installation: Connecting the UPAM to a Self-AmplifiedPaging SystemConnection to a self-amplified system usually consists of connecting the

Seite 20

Connecting the UPAM to a Self-amplified Paging System (cont'd)Figure 10. Typical Connection to a Self-Amplified Paging System[27]

Seite 21

Functional Test GuideUse the following chart to verify proper operation after installation. To start the test,pick up a telephone and call the UPAM.[2

Seite 22 - Hi-Z AUX Input

Procedure A1.Disconnect the UPAM from the telephone equipment.2.Confirm that the power supply is properly connected and that the MODE switches are int

Seite 23

[3]Contents1. Product Identification...5UPAM Universal Paging Access Mo

Seite 24 - MIC Input

Troubleshooting (cont'd)Procedure B1.2.3.4.Disconnect the UPAM from the paging system.Connect a test set to PT & PR terminals on UPAM (see Fi

Seite 25

[4]This page left blank intentionally.

Seite 26 - Paging System

1.Product IdentificationUPAM Universal Paging Access ModuleThe UPAM Universal Paging Access Module is designed to provide telephoneaccess to most comm

Seite 27

[6]Features24V or 48V Operation MODE switches let you select 24V (not included) or 48V (included)(Trunk Port Operation) power supply. A 48-volt power

Seite 28 - 4. Troubleshooting

[7]2. Connection to the TelephoneSystemGeneral InstructionsOverview This section contains installation procedures for connection to the telephone syst

Seite 29

[8]General Instructions (cont’d)MODE Switches (on front of unit) A set of 5 MODE switches (S1 through S5, see Figure 1 on page 5) is included toset th

Seite 30 - Troubleshooting (cont'd)

[9]Specific InstructionsTrunk Port Connections - Loop Start NOTE: Controls for VOX DELAY, PAGING TIME, MODE Switch S5 and AUX switchesS1, S2, S3, and