Chapter 2 Fault Management System 223
Business Communications Manager - Management User Guide
Event ID: 265 Message: When seizing a trunk to make an outgoing call a handshake must
occur between the Call Server trunk and the network before digits can
be dialled. This event indicates that this handshake failed since the
network did not acknowledge the Call Server request to seize the line.
The trunk is unusable until the handshake is properly completed. Port
= %1. Check the trunk interface with the network to determine if it
operating correctly.
User action: Check the trunk interface with the network to determine if it operating
correctly.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 265, Sev=P7, Cat=C
Event ID: 270 Message: Invalid Message. The Call Server is dealing with a multi byte message
that it does not understand while trying to initialize a set. TN = %1. If
the event occurs many times, unplug the set, wait for 3 minutes, then
replug the set. May be caused by a noisy line.
User action: If the event occurs many times, unplug the set, wait for 3 minutes, then
replug the set.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 270, Sev=P8, Cat=A
Event ID: 271 Message: A set has firmware that is incompatible with the current Call Server
load. Customer should contact installer to change Call Server load or
the set.
User action: Customer should contact installer to change Call Server load or the
set.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 271, Sev=P8, Cat=A
Event ID: 323 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of a
degraded minute. The module is in a no-new-calls state. DTCM = %1.
Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 323, Sev=P5, Cat=C
Event ID: 324 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of a
severely errored second. The module is in a no-new-calls state. DTCM
= %1. Intervention is required to find out why the Digital Trunk
Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 324, Sev=P5, Cat=C
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary
Seitenansicht 226
1 2 ... 222 223 224 225 226 227 228 229 230 231 232 ... 487 488