226 Chapter 2 Fault Management System
P0609330 2.0
Logs: MSC event 334, Sev=P5, Cat=C
Event ID: 335 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
remote alarm indication in time slot 16. The module is in a
no-new-calls state. DTCM = %1. Intervention is required to find out
why the Digital Trunk Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 335, Sev=P5, Cat=C
Event ID: 367 Message: A reset has occurred in the Basic Rate Interface or Digital Trunk
Interface module. This event should only occur when the system first
boots.
User action: Obtain the traceback for the module that reset.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 367, Sev=P5, Cat=B
Event ID: 400 Message: A warm start has been done. No action required.
User action: No action required.
Alarm severity: Warning
Trap-type: Information
Logs: MSC event 400, Sev=P9, Cat=E
Event ID: 401 Message: A search of the terminal address table failed to find a TN that matched
the TN of the device that is initializing and requesting its LAD. The
device will fail to initialize. This is a software error that can occur on
initialization of any TCM peripheral. Report the problem and the
software version.
User action: Report the problem and the software version.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 401, Sev=P4, Cat=B
Event ID: 608 Message: Attempt to attach a device type to a port that is not supported in the
software. The device will not initialize nor be operational. Verify that all
types of attached peripherals initialize and function. Remove any
unsupported device types.
User action: Verify that all types of attached peripherals initialize and function.
Remove any unsupported device types.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 608, Sev=P6, Cat=F
Event ID: 617 Message: Cannot acquire a session. This happens only on Companion devices.
Contact the installer to get the traceback data.
User action: Contact the installer to get the traceback data.
Alarm severity: Minor
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary