Parameter: Multiline Select Algorithm
Path: Configuration Manager > XCVR, FDDI, HSSI, MCT1, or COM connector
configured for RSVP > Edit Connector window > Edit Line Resources
Default: First Fit
Options: First Fit
|
Round Robin
Function: Specifies how the Resource Manager selects which line to use for a new
resource request, if you have the Resource Manager configured on a multiline
circuit.
Instructions: Set this parameter only if you configured the Resource Manager on a multiline
circuit.
Select First Fit to always use the first available line that can service reserved
traffic requests. Select Round Robin to rotate the use of lines available to service
requests. All lines for a circuit must use the same algorithm. If any one line on a
circuit specifies First Fit, all lines use the first fit algorithm.
MIB Object ID: 1.3.6.1.4.1.18.3.5.16.2.1.3.1.11
Parameter: Multiline Threshold Bandwidth
Path: Configuration Manager > XCVR, FDDI, HSSI, MCT1, or COM connector
configured for RSVP > Edit Connector window > Edit Line Resources
Default: 0
Options: 0 to 214,748,364 b/s
Function: Specifies how the first fit algorithm works, providing you set the Multiline
Select Algorithm parameter to First Fit. If you accept the default value, the
Resource Manager uses the simple first fit algorithm. If you select a value
greater than 0, the Resource Manager still uses the first available line with
reservable bandwidth to service requests, but moves to the next available line
after reaching the configured threshold. When all lines are at their thresholds,
the Resource Manager resumes using the simple first fit algorithm.
Instructions: Set this parameter only if you have configured the Resource Manager on a
multiline circuit and have set the Multiline Select Algorithm parameter to First
Fit.
Accept the default or enter a number less than the value of the Reservable
Bandwidth parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.16.2.1.3.1.12