Avaya Configuring SDLC Services Bedienungsanleitung Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 74
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
Editing SDLC Parameters
114053 Rev. A 4-13
Parameter: Total Link Station Limit
Default: 16
Range: 1 through 254
Function: Specifies the total link station activation limit.
Instructions: Enter the number of link stations (from 1 through 254) that you want to
reserve for inbound and outbound activation on this port.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.2.1.30
Parameter: Inbound Link Station Limit
Default: 8
Range: 1 through 254
Function: Specifies the inbound link station activation limit.
Instructions: Enter the number of link stations (from 1 through 254) that you want to
reserve for inbound activation on this port.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.2.1.31
Parameter: Outbound Link Station Limit
Default: 8
Range: 1 through 254
Function: Specifies the outbound link station activation limit.
Instructions: Enter the number of link stations (from 1 through 254) that you want to
reserve for outbound activation on this port.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.2.1.32
Seitenansicht 50