Seitenansicht 210
Appendix B BRI wiring chart 211
Installation and Maintenance Guide
Appendix B
BRI wiring chart
The digital BRI ISDN lines connects to the BCM50b, BCM50ba, and BCM50be main units
through the BRI ports (RJ-45) on the front of the main units. See the figure BRI ports and pin out
(BCM50b shown) on page 211.
The figure BRI ports and pin out (BCM50b shown) on page 211, the table BRI port wiring on page
211, and the table BRI line numbering on page 212 apply to S-Loop and T-Loop connections.
S-Loop are used to connect S-Loop devices such as video phones, terminal adapters, and Grp 3
Fax machines. The T-Loops are used to connect to the CO/PSTN.
Figure 88 BRI ports and pin out (BCM50b shown)
The table BRI port wiring on page 211 and the table BRI line numbering on page 212 list the
wiring details for the RJ-45 ports.
Warning: For a U-loop connection, the BRI port must be connected only to an NT1
provided by the service provider. The NT1 must provide a Telecommunication Network
Voltage (TNV) to Safety Extra Low Voltage (SELV) barrier.
Table 35 BRI port wiring
Pin Signal Signal on system side
1 No connection No connection
2 No connection No connection
3 + Receive (+Rx) +Tx
4 + Transmit (+Tx) +Rx
5 - Transmit (-Tx) -Rx
6 - Receive (-Rx) -Tx
7 No connection No connection
8 No connection No connection
BRI port pin out
BRI ports