ADID wiring chart
Analog telephone lines connect to the ADID4 or ADID8 through the RJ-21 connector on the front
of the media bay module (MBM). See the figure ADID RJ-21 connector on page 223.
Figure 94 ADID RJ-21 connector
The table ADID4 and ADID8 RJ-21 connector wiring on page 223 lists the wiring details for the
RJ-21 connector on the ADID4 and ADID8. Use the first four lines for the ADID4 and use all
eight lines for the ADID8.
Table 45 ADID4 and ADID8 RJ-21 connector wiring
Line Pin Connection
Default line numbers on
Expansion port 1
Default line numbers on
Expansion port 2
1
26 Tip
065 095
1Ring
2
27 Tip
066 096
2Ring
3
28 Tip
067 097
3Ring
4
29 Tip
068 098
4Ring
5
30 Tip
073 103
5Ring
6
31 Tip
074 104
6Ring
7
32 Tip
075 105
7Ring
8
33 Tip
076 106
8Ring
RJ-21 pin outRJ-21 connector