Configuring BayStack Remote Access
B-12 117341-A Rev. A
The possible settings for synchronous connectors are as follows:
EZ-Install (the default setting)
The IP address, next-hop IP address, subnet mask, and WAN protocol (Bay
Networks Standard PPP or Frame Relay)
The possible settings for Ethernet connectors are as follows:
None (the default setting)
The IP address with subnet mask and next-hop IP address (if you configured
one)
The possible settings for token ring connectors are as follows:
None (the default setting)
The IP address with subnet mask, ring-speed option, and next-hop address (if
you configured one)
See Chapter 4 for instructions on using the ifconfig and bconfig commands to
change the parameter settings.
Debugging the BootP Server
Debug the BootP server as follows:
1. Enter the following command at the UNIX command line:
bootpd -d -d&
The bootpd debugger tool reads the /etc/bootptab file and generates the
/etc/bootpd.dmp file. The /etc/bootpd.dmp file contains the portion of the
/etc/bootptab file that the bootpd debugger could read successfully. The
debugger displays messages such as the following:
[1] 12914
hostname:/etc> reading "/etc/bootptab"
read 19 entries from "/etc/bootptab"
dumped 19 entries to "/etc/bootpd.dump".
2. Compare the bootptab file with the bootpd.dmp file.
If the bootpd.dmp file is truncated or is otherwise different from the bootptab
file, BootPD may have encountered a syntax error. Find the inconsistency in