Seitenansicht 64
Entering Commands
117383-B Rev. 00
3-7
Configuration Commands
This section describes how to enter BCC configuration commands using any of
the following formats:
Basic (full) syntax
Default syntax
Abbreviated syntax
BCC syntax consists of object names, parameter names and values, and various
types of punctuation. Note in particular that
All object and parameter names appear as one word (hyphenated where
necessary) in the BCC command line.
Parameters have either a single value or multiple values enclosed in braces
{x y z} in the command line. You either accept the default value or supply a
value for each parameter associated with a configurable object.
Parameters and their values must appear as a pair in the same command line.
Using Basic (Full) Syntax
The basic or full syntax for BCC commands consists of the following required and
optional elements:
{
<object-name>
} {
<required_parameter>
<value>
... } ...
<parameter> <value>
...
<parameter> <value>
The BCC requires input for any elements enclosed by braces ({ }).
{<object-name>} is the name of an object you want to configure (for example,
ip
)
The BCC assumes that an object you specify is new (and will create it) if it is not
in the current configuration. If an object you specify already exists in the current
configuration, the BCC assumes that you want to modify that object.
Caution:
Configuration commands and
source
commands make real-time
changes to the device configuration.
Seitenansicht 64