Entering Commands
117383-B Rev. 00
3-9
box# ethernet
Required parameter "slot" was not specified for ethernet.
Usage: "ethernet slot <value> connector <value>"
Or: "ethernet <slot>/<connector>"
The following commands are equivalent.
Using full syntax:
box# ethernet slot 2 connector 1
ethernet/2/1#
Using default (minimum) syntax:
box# ethernet 2/1
ethernet/2/1#
ethernet is the object you want to configure.
slot and connector are the required parameters of ethernet on AN/ANH, ARN,
and BN platforms.
The ability to configure objects using only the values for required parameters is
the “minimum to configure” feature of the BCC. Typically, the BCC requires you
to enter the values but not the names of required parameters. In some cases,
however, the BCC requires you to explicitly enter the name of a required
parameter along with its value. (The usage Help indicates the command elements
you need to enter.)
Using Abbreviated Syntax
You can abbreviate BCC configuration commands, as follows:
Example: (BN router)
box# eth 2/1
This is the same as either of the following two commands:
box# ethernet slot 2 connector 1
box# ethernet 2/1
The BCC completes or expands abbreviated object and parameter names when
you press Return.