Customizing AHB Services
300017-A Rev. 00
3-3
To set the auto learn method by which AHB learns bridge entries, complete the
following tasks:
Configuring a Local AHB Init File
AHB Init files are ASCII data files that you can use to manually add bridge table
entries and or configure PVCs on an AHB interface. You create the init files
locally, but must store them on the router’s flash memory card. AHB reads the init
files from the router’s flash memory when the router boots.
The AHB init files contain an extra flag on each entry that indicates where AHB
should create the corresponding PVC identified in the bridge entry, if it does not
already exist.
Sample Init File
In the AHB init file, there is a section for each router slot that has configured
bridge entries. Slots that do not contain hosts do not need a section header. Within
a section, there is one line for each bridge entry.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
IP
. The IP menu opens.
3. Choose
AHB
. The AHB menu opens.
4. Choose
Global
. The Edit ATM Half-Bridge Global
Parameters window opens.
5. Set the
Auto Learn Method
parameter.
Click on
Help
or see the parameter
description on page A-3.
6. Click on
OK.
You return to the Configuration Manager
window.