System show Commands
117383-D Rev 00
D-5
Parity Serial port’s current parity setting.
Stop Bits Number of stop bits in the serial port’s configuration.
Modem Enable Configuration of modem control, as follows:
Disabled
- Port is directly connected to a device, such as a
dummy terminal or a terminal server.
Enabled
- Port is attached to a modem and modem leads are
enabled.
Lines/Screen Number of lines that the serial port displays before displaying the
more prompt.
More Enable Setting of the Technician Interface
more
feature: Enabled or
Disabled (according to the MIB record). The Technician Interface
more
command affects only the current login session; it does not
change the MIB, and so does not affect the setting of this field.
Port Prompt Technician Interface prompt.
Login Retries Maximum number of login retries; relevant only if modem control is
enabled. This value determines the maximum number of failed login
attempts that a system allows on the serial port. If the maximum
occurs, the system hangs up on the line, causing a modem
connection to lose carrier detect.
Login Timeout
(min.)
Number of minutes allowed between when the system displays the
login banner and a user enters a login ID; relevant only if modem
control is enabled. If this timeout occurs, the system hangs up on
the line.
Password Time Out Number of minutes allowed to enter a password. If this timeout
period expires, the system hangs up on the line.
Command Time
Out
Command line timeout value; relevant only if modem control is
enabled. If you do not enter a command in this number of minutes,
the system hangs up on the serial port.
User Abort Logout Switch to execute control (^C) to break out of the user autoscript.
When a user autoscript is in effect and this parameter is enabled,
you can break out of the script when logged in as User, but not as
Manager. Also, if this parameter is enabled and the script
terminates due to an error, the system automatically logs you out.
Initial Search Path List of file system volumes to be searched when you run a script
without a volume specifier or if an autoscript does not contain a
volume specifier. The environment variable PATH is set to this
string. The string format is as follows:
<vol>
:[;
<vol>
: ...]
Example: 2:;3:;4:;5: