Seitenansicht 51
Remote Loopback Test
This test requires compatible AT&T equipment at the remote end.
The remote loopback test ensures that no problems with data transmission are occurring in the
data transfer circuit. When you initiate a remote loopback test, data is transmitted from the data
terminal, through your ADM and the network to the data module at the far-end, where it is
looped back to your ADM. A data call must be established before you initiate a remote loopback
test.
To initiate a remote loopback test:
1 Establish a data call.
2 Rapidly type the Attention sequence (default value is +++).
3 Type at the CMD: prompt:
test remote
.
The ADM will display:
REMOTE LOOPBACK TEST
ENTER ATTENTION SEQUENCE TO END TEST
Or, if you are not on a data call, the ADM’s response is:
Test Remote cannot be used at this time
4 Type characters on your terminal keyboard and check to see that they are being echoed as
typed.
If you find no errors, the ADM passed the test.
5 Rapidly type the Attention sequence (default value is +++) to end the test. Ending the test
does not end the call. You will return to local mode, and the ADM will be ready to transmit
data.
Call Status: Data Call Active
Type H for help.
6 At the CMD: prompt, type
continue
to return to Data Mode.
Loopback Test.)R