Digital trunk clock source
About this task
Digital trunks require the telephone system at each end of the trunk to share a clock signal to
ensure synchronization of call signalling. The B5800 Branch Gateway can obtain and use the
clock signal from any of its digital trunks. Typically the clock signal provided by a digital trunk
from the central office exchange is used as this will be the most accurate and reliable clock
source.
To do this, the Clock Quality setting on each line in the B5800 Branch Gateway configuration
is set to one of the following:
Network
If available, the clock signal from this trunk should be used as the B5800 Branch Gateway
clock source for call synchronization. If several trunk sources are set as Network, the
B5800 Branch Gateway will default to using one as detailed below.
Fallback
If available, the clock signal from this trunk can be used as the clock source if none of the
trunks set as Network are providing a clock source.
Unsuitable
The clock source from this trunk will never be used as the B5800 Branch Gateway clock
source.
If no clock source is available the B5800 Branch Gateway can use its own internal clock if
necessary.
In the example below the first B5800 Branch Gateway is set to use the public network trunk
as its clock source and ignoring the possible clock source from the QSIG trunk. The other
B5800 Branch Gateway system is using the clock signal received from the first B5800 Branch
Gateway on its QSIG trunk as its clock source. Thus both systems are using the same clock
source and that clock source is the public network exchange.
When multiple trunks with the same setting are providing clock signals, trunks are used in the
order of slots 1 to 4 and then by port on each slot.
The current clock source being used by an B5800 Branch Gateway system is shown on the
Resources page within the B5800 Branch Gateway System Status Application.
Digital trunk clock source