Troubleshooting Routers
A-28
# 104: mm/dd/yy 13:13:53.406 DEBUG SLOT 2 MODEMIF Code: 9
Connector COM1: modem present V.25bis mode
# 105: mm/dd/yy 13:13:53.406 DEBUG SLOT 2 SWSERV Code: 46
Line Mgr received line ready for line 1
# 106: mm/dd/yy 13:13:53.406 INFO SLOT 2 SWSERV Code: 10
Sync Line 1 available for dial on demand pool 1.
# 107: mm/dd/yy 13:13:53.406 INFO SLOT 2 SYNC Code: 11
Connector COM1 providing LLC1 service.
MCT1 Log Information in a Lab Testing Environment
The following log messages show what happens when you access the Line Tests
option and use Port 2 of an MCT1-2 in Slot 5 to send a payload loopback to Port 1
of an MCT1-2 Slot 4. During this test, the yellow loopback LED lights on Port 1
in Slot 4.
When you enter the Technician Interface script command
show ds1e1 port, the
Technician Interface accesses the MCT1.bat file and the MIB, and displays the
MCT1-2 port setup.
[3:1]$ show ds1e1 port
DS1E1 Port Status:
------------------
2 entries in table.
When the remote slot (Slot 4) receives a loop-up or loop-down command, the
remote loopback yellow LED lights and the following messages appear in the log:
# 2: mm/dd/yy 08:56:17.563 INFO SLOT 4 DS1E1 Code: 55
Connector COM2 received loop-up code
# 18: mm/dd/yy 09:08:47.872 INFO SLOT 4 DS1E1 Code: 56
Connector COM2 received loop-down code
# 3: mm/dd/yy 10:31:12.638 INFO SLOT 2 MIB Code: 5
wfDs1E1ActionEntry.5.905102 set to 5
# 4: mm/dd/yy 10:31:12.683 INFO SLOT 4 DS1E1 Code: 30
Connector COM1 Unscheduled FDL message received - type Payload Loopback
Activate.
# 5: mm/dd/yy 10:31:12.687 INFO SLOT 4 DS1E1 Code: 22
Slot Conn State MTU Loopback
State
Accept
Loopback
BERT
Mode
Line
Type
Line
Coding
FDL
Type
FDL
Addr
4 1 Loopback 1600 Net
Payload
Enabled Off ESF B8ZS ANSI BY
5 2 Up 1600 No Loop Enabled Off ESF B8ZS ANSI BY