
Reading the Event Log
A-31
Connector COM1, Logical Line 1 time_slot = 23.
Connector COM1, Logical Line 1 time_slot = 24.
Connector COM1, Logical Line 1 initialization complete
Environment address - 30ea8ba0 Line record address - 30f30dc4
Hardware map address - 30f2da34 Initialization block -
80006800
Receive descriptor ring - 80001000 Transmit descriptor ring -
80003c00
# 8: mm/dd/yy 10:38:39.367 DEBUG SLOT 4 PCAP Code: 67
interface became local - line 10904101
intf gate spawned - line 10904101
# 9: mm/dd/yy 10:38:39.371 DEBUG SLOT 4 PCAP Code: 65
wait_state - line 10904101
# 10: mm/dd/yy 10:38:44.351 DEBUG SLOT 5 DP Code: 67
Missing Circuit Options record cct #3.
DP gate rcv'd LINE message for cct 3.
# 11: mm/dd/yy 10:38:44.355 DEBUG SLOT 5 DP Code: 23
Creating Circuit 3 soloist with line GH 0xb381
# 12: mm/dd/yy 10:38:44.355 DEBUG SLOT 5 GAME Code: 23
SOLO (0x00403): election opening 3c000000/3c000000 (3c000000)
vote=00000000
# 13: mm/dd/yy 10:38:44.386 DEBUG SLOT 5 GAME Code: 97
SOLO (0x00403): election WON 0x04000000 (repl=bc000009/3c000000)
SOLO (0x00403): election CLOSING 3c000000/3c000000 (3c000000)
vote=00000000
# 14: mm/dd/yy 10:38:44.390 INFO SLOT 5 ARP Code: 1
Service is up on circuit 3
The following command displays the new port status:
[3:1]$ show ds1e1 port
DS1E1 Port Status:
------------------
2 entries in table.
If you access the Line Tests option and send the FDL Line Loop CI, IA, or IB
types, the following messages appear:
# 3: mm/dd/yy 10:43:14.207 INFO SLOT 2 MIB Code: 5
wfDs1E1ActionEntry.5.905102 set to 1
# 4: mm/dd/yy 10:43:14.207 INFO SLOT 5 DS1E1 Code: 22
Slot Conn State MTU Loopback
State
Accept
Loopback
BERT
Mode
Line
Type
Line
Coding
FDL
Type
FDL
Addr
4 1 Up 1600 No Loop Enabled Off ESF B8ZS ANSI BY
5 2 Up 1600 No Loop Enabled Off ESF B8ZS ANSI BY
Kommentare zu diesen Handbüchern