Configuring ATM Services
4-22
117374-B Rev. 00
Defining Retransmissions
The ATM circuit can retransmit a specified number of RESTART and STATUS
ENQUIRY messages before it considers the link down. You can control how
many of these messages the circuit retransmits.
Setting the Number of Allowable Restart Messages
By default, the circuit can retransmit three RESTART messages before it
considers the link down. However, you can set the number of RESTART
messages that the circuit can send to a value from 1 to 100.
Using the BCC
To change the number of times the ATM circuit can retransmit RESTART
messages, navigate to the signaling timer prompt (for example,
box; atm/11/1; signaling/11/1; timers/11/1
) and enter:
restarts-retransmitted
integer
integer is the number of times a circuit can retransmit RESTART messages.
For example, the following command changes the number of times to 8:
timers/11/1#
restarts-retransmitted 8
timers/11/1#
4. Click on
Done
. You return to the Edit ATM Connector
window.
5. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
(continued)