Configuring ATM Services
4-64
117374-B Rev. 00
Setting the SSCOP Maximum Poll Data Value
The SSCOP maximum poll data value sets the maximum value of the poll data
state variable before transmitting a POLL PDU. The poll data state variable
increments upon transmission of an sequenced data PDU and resets to 0 upon
transmission of a POLL PDU.
By default, the maximum poll data value sets the poll data state to 25. However,
you can set this parameter to any value from 1 to 120.
Using the BCC
To change the maximum poll data value, navigate to the SSCOP prompt (for
example,
box; atm/11/1; signaling/11/1; sscop/11/1
) and enter:
pd-before-poll-maximum
integer
integer is the count value that you want the controller to use.
For example, the following command changes the maximum poll data value to 50:
sscop/11/1#
pd-before-poll-maximum 50
sscop/11/1#
Using Site Manager
To change the maximum poll data value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling AAL (SAAL)
. The ATM Signaling AAL Records List
window opens.
3. Set the
Max PD Before Poll
parameter.
Click on
Help
or see the parameter
description on page A-56.
4. Click on
Done
. You return to the Edit ATM Connector
window.
5. Click on
Done
. You return to the Configuration Manager
window.