Editing DLSw Parameters
303523-A Rev. 00
5-43
2.
Type the 0x prefix and then enter a hexadecimal value for the SAP
parameter.
Valid SAP addresses include even values 00, 04 to EC, and F0.
3.
Click on OK.
This saves your entry to the router configuration file. The DLSw SAP
Configuration window reappears (refer to Figure 5-16
) with the new entry
added to the list of existing DLSw SAPs.
4.
Repeat Steps 1 through 3 for each SAP that you want to add.
5.
Click on Done.
The Configuration Manager window reappears.
Following is a description of the SAP parameter.
Parameter: SAP
Default: None
Options: A valid even SAP address (00 to F0) in hexadecimal format
Function: Specifies the destination SAP address associated with a communication
subsystem on a remote device (for example, on a PC or host).
Instructions: Begin the address with 0x and type the SAP address associated with a
specific communication subsystem. For example, the SAP associated with
NetBIOS is 0xF0.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.4.1.2
Editing a DLSw SAP Table Entry
You can edit only the SAP Window (flow control) parameter associated with an
existing DLSw SAP Table entry.
Note:
After you add an entry to the DLSw SAP Table, Site Manager disallows
any attempt to edit the SAP address associated with that entry. To change the
address of an existing DLSw SAP, you must delete the entry in the DLSw SAP
Configuration window, and then add a new SAP with the new address. Refer to
the preceding section, “Adding a DLSw SAP Table Entry,” for information
about how to add a new DLSw SAP.
Kommentare zu diesen Handbüchern