Customizing TDM
309426-14.10 Rev 01
2-13
Disabling or Reenabling Data over a TDM Circuit
By default, when you create a TDM circuit, data traffic over that circuit is
enabled. You can disable and reenable the traffic over a TDM circuit. Changing
the state of the traffic over a TDM circuit is useful, for example, when you want to
hang up (disable) a conference call.
Using the BCC
To disable traffic over a TDM circuit, navigate to the dual synchronous connector
prompt (for example,
box#; dsync 3/1/1
) and enter:
state disabled
To enable traffic over a TDM circuit, navigate to the dual synchronous connector
prompt (for example,
box#; dsync 3/1/1
) and enter:
state enabled
Using Site Manager
To disable or reenable traffic over a TDM circuit, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the PORT connector.
The Edit Connector window opens.
2. Click on
Edit Line
. The Edit DSYNC PMC Parameters
window opens.
3. Set the
Enable
parameter. Click on
Help
or see the parameter description on
page A-3.
4. Click on
OK
. You return to the Edit Connector window.
5. Click on
Done
. You return to the Configuration Manager
window.
Kommentare zu diesen Handbüchern