Site Manager Parameters
309426-14.10 Rev 01
A-3
Dual Synchronous PMC Parameters
The dual synchronous PMC parameters determine the behavior of the TDM
circuit on an individual timeslot basis.
Parameter: Enable
Path: Configuration Manager > Connector > Edit Line
Default: Enable
Options: Enable | Disable
Function: Enables traffic over a TDM circuit.
Instructions: Select Enable to enable traffic over a TDM circuit. Select Disable to disable
traffic over a TDM circuit.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.9.3.5.1.2
Parameter: Per-Timeslot Subrate
Path: Configuration Manager > Connector > Edit Line
Default: Subrate_64K
Options: Subrate_64K | Subrate_56KMSB | Subrate_64KLSB
Function: Specifies data rate for each timeslot within a TDM circuit.
Instructions: Accept the default, 64K, for a full timeslot. Select 56KMSB to send 56 Kb/s
data and set the first bit on the wire and have data carried on the next 7 bits.
Select 56KLSB to send 56 Kb/s data and carry data on the first 7 bits and set the
last bit to 1.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.9.3.5.1.7
Parameter: Number of Timeslots
Path: Configuration Manager > Connector > Edit Line
Default: 1
Options: 1 through 32
Function: Number of TDM circuit timeslots occupied by this interface. Since TDM
circuits are full-duplex, setting this attribute to N will allocate N transmit
timeslots and N receive timeslots.
Instructions: Accept the default or select a value from 1 to 32.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.9.3.5.1.8