Seitenansicht 474
303560-A Rev 00
2-427
enabled
Displays the circuits that a user has enabled. In this case, State is Down, Init, Not Present,
or Up. For definitions of the columns in the table, refer to the
alerts
command.
Sample Display - show isdnbri enabled
ISDN BRI Modules Enabled:
--------------------------
receive errors
Displays receive error information for all circuits or for a specified circuit.
Sample Display - show isdnbri receive errors
ISDN BRI Module Receive Errors:
-------------------------------
Over Frames
Slot Conn Flows Bad CRC Aborts Too Long
---- ---- ---------- ---------- ---------- ----------
1 12 0 0 0 0
1 32 0 0 0 0
Slot
-----
Conn
----
State
-----
DSL
ID
----
Line
Number
------
MTU
---
TE State
---------
BChannel
Loopback
--------
Tmr
3
---
Tmr
4
---
1 12 Init 0 1301102 400 Deactivated Disabled 10 750
1 32 Init 1 1301302 400 Activated Disabled 10 750
Slot Slot identifier; ranges from 1 to 14.
Conn Connector’s instance identifier; ranges from 1 to 4.
Over Flows Number of data overflows (anomalies) received by the circuit.
Bad CRC Number of bad cyclic redundancy checks received.
Aborts Number of abort messages received.
Frames Too Long Number of frames received that were too long for processing.
(They exceeded the standard ISDN frame length.)