Using Technician Interface Scripts
2-648
303560-A Rev 00
backup_dialing schedules
Displays the scheduled availability of the backup circuits in a backup pool. The display
includes the following information:
Sample Display - show sws backup_dialing schedules
Switched Services Backup Schedule Information
---------------------------------------------
Circuit Pool Day(s) Start Time End Time
----------- -------- ---------- ---------- --------
S11 1 Not Configured
S21 3 Weekday 0 2359
Tuesday 0 2359
S31 3 Not Configured
Total of 3 Backup Circuits.
bandwidth circuit
Displays all circuits that are configured for bandwidth-on-demand. The display includes
the following information:
Circuit Identifies the name of the circuit.
Pool Specifies the backup pool that the circuit uses.
Day(s) Days that the circuit is available.
Start Time The beginning of the time interval that the circuit is available.
End Time The end of the time interval that the circuit is available.
Primary Circuit Name of the primary circuit.
Bandwidth Pool ID number of the bandwidth-on-demand pool; ranges between
1 to 255.