Site Manager Parameters
117374-C Rev 00
A-23
Parameter: Administrative State
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Service
Attributes > PVC
Default: Up
Options: Up | Down
Function: Specifies the administrative state of the PVC. The Up state indicates that traffic
flow is enabled on this PVC. The Down state indicates that traffic flow is
disabled on this PVC.
Instructions: Accept the default, Up, if you want traffic to flow on this PVC. Set the state to
Down if you do not want traffic to flow on this PVC.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.5.1.5
Parameter: Xmit Peak Cell Rate (cells/s)
Path: Configuration Manager > Circuits > Edit Circuits > Edit > ATM > Service
Attributes > PVC
Default: 2358
Options: 128 to 353207 (ATM ARE OC-3 SONET/SDH ILI pairs and
Model 5782 ATM routers)
128 to 96000 (ATM ARE DS-3 ILI pairs)
128 to 80000 (ATM ARE E-3 ILI pairs; G.832 framing mode)
128 to 72000 (ATM ARE E-3 ILI pairs; G.751 framing mode)
Function: Specifies the upper traffic limit, in cells/s, that the ATM connection can submit.
How you set the peak cell rate depends on:
• The optical transmission rate of your ATM device
• The amount of traffic you expect on a particular VC
• The rate you want for each VC
Instructions: After you determine the transmission rate of your ATM device, set the peak cell
rate within the specified range.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.5.1.8