Site Manager Parameters
117374-C Rev 00
A-43
Parameter: VPI
Path: Configuration Manager > Protocols > ATM > ATM Signaling
and
Configuration Manager > Circuits > Edit Circuits > Edit > ATM > ATM
Signaling
Default: 0
Options: 0 to 255
Function: Specifies the virtual path identifier (VPI) for the signaling VC. The signaling
VC is a dedicated VPI/VCI pair reserved for signaling messages.
Instructions: Accept the default value, 0, or enter a value from 0 to 255.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.13
Caution:
The signaling VC (0/5) and the ILMI VC (0/16) are reserved. These
VCs remain in an operational state as long as signaling is enabled on the ATM
interface. Because most ATM devices use these VPI/VCI pairs for signaling,
Bay Networks recommends that you not change these values.