Monitoring ATM Using the BCC show Command
117374-C Rev 00
B-27
show sonet current
The
show sonet current
command displays portions of the SONET entries table.
The output includes the following information:
Slot/<Module>/Conn The slot, module, and connector number of the SONET circuit.
Circuit Name of the circuit associated with this line.
Sec into Interval The number of seconds into the current 15-minute interval.
# of Intervals The number of complete 15-minute intervals.
Line Coding The line coding on this circuit. The line coding options are:
•B3ZS
HDB3
Line Type Status The line status of the interface. The possible status values are:
NoAlarm
- no alarm present
RRAI
- receiving yellow remote alarm indication
TRAI -
transmitting yellow remote alarm indication
RAIS
- receiving Alarm Indications Signal (AIS) failure state
TA I S
- transmitting AIS failure state
LOF
- receiving Loss of Frame (LOF) failure state
LOS
- receiving Loss of Signal (LOS) failure state
Loopback
- looping the received signal
TestCode
- receiving a test pattern
LowSignal
- low signal
Line Stats
Slot/<Module>/Conn The slot, module, and connector number of the SONET circuit.
Circuit Name of the circuit associated with this line.
Interval The current interval.
LESs The number of line errored seconds (LESs) in the current interval.
An LES is a second in which one or more coding violations occurred
or one or more LOS defects were detected.
SEFSs The number of severely errored framing seconds (SEFSs) in the
current interval. An SEFS is a second with one or more OOF errors
or an AIS defect.
UASs The number of unavailable seconds (UASs) in the current interval.
LCVs The number of line coding violations (LCVs) in the current interval.
A line coding violation is a count of both bipolar violations (BPVs)
and excessive zero (EXZ) error events.