DLSw Service Parameters
304233-A Rev. 00
A-35
Parameter: Destination (Host) MAC (hex)
Path:
Configuration Manager > Protocols > DLSw > Local Devices
Default: None
Options: Any standard MSB Token Ring MAC address
Function: Identifies (with the Destination SAP) the Token Ring or Ethernet host that the
local device will reach using SDLC services. This parameter must match the
MAC address of the LAN gateway, using MSB (Token Ring) format.
Instructions: Consult your host system manager for the host MAC address; then enter the
12-digit hexadecimal address.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.12.1.8
Parameter: Destination (Host) SAP (hex)
Path:
Configuration Manager > Protocols > DLSw > Local Devices
Default: 0x4
Options: 0x01 to 0xFE
Function: Identifies (with the Destination MAC) the Token Ring or Ethernet host that the
local device will reach using SDLC services. This parameter must be entered
into the SAP Table of the source and destination routers. The default (04) is
included in the default SAP Table.
Instructions: Consult your host system manager for the host SAP address. Enter the 0x prefix
followed by a one-digit or two-digit hexadecimal address.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.12.1.9
Parameter: MAXOUT
Path:
Configuration Manager > Protocols > DLSw > Local Devices
Default: 7
Range: 1 to 127
Function: Controls the maximum number of consecutive frames that an SDLC link station
can send without acknowledgment.
Instructions: Enter a value from 1 to 127.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.5.1.10