Configuring IP, ARP, RIP, and OSPF Services
5-12
117356-E Rev 00
Using Site Manager
To enable or disable triggered updates, complete the following tasks:
Specifying a Time-to-Live Value
By default, RIP inserts a time-to-live (TTL) value of one hop into each outbound
routing update. Setting a TTL of 1 prevents RIP updates from inadvertently
exiting the local network. Increasing the TTL introduces the risk of the update
exiting the local network and being forwarded around the network.
Certain RIP implementations ignore packets with a TTL value of 1. Use this
parameter to provide interoperability with such implementations.
You can use the BCC or Site Manager to specify a TTL value greater than 1.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
IP
. The IP menu opens.
3. Choose
RIP Interfaces
. The IP RIP Interface Configuration
window opens.
4. Click on the RIP interface that you want to
edit.
The parameter values for that interface
appear in the IP RIP Interface
Configuration window.
5. Set the
Triggered Updates
parameter.
Click on
Help
or see the parameter
description on page A-67.
6. Click on
Apply
, and then click on
Done
. You return to the Configuration Manager
window.