Site Manager WAN Line Services Parameters
117021-A Rev. A A-39
Parameter: Interframe Time Fill Character
Path: Configured MCE1 or MCT1 Connector > MCE1/T1 Logical Lines
Default: Flags
Options: Flags
| Idles
Function: Specifies the interframe time-fill pattern for transmission across this circuit.
Flags selects an 0x7E pattern (0 1 1 1 1 1 1 0); Idles selects an 0xFF pattern
(1 1 1 1 1 1 1 1).
Instructions: Set the line interframe time-fill character.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.19
Parameter: CRC Size
Path: Configured MCE1 or MCT1 Connector > MCE1/T1 Logical Lines
Default: 16 bit CRC
Options: 32 bit CRC
| 16 bit CRC
Function: Specifies the CRC type. With 16-bit CRC, the router appends a 16-bit CRC to
the transmitted frames and performs a 16-bit CRC on received frames. With
32-bit CRC, the router appends a 32-bit CRC to transmitted frames and
performs a 32-bit CRC on received frames.
Instructions: Set the CRC size.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.20
Parameter: MTU Size (bytes)
Path: Configured MCE1 or MCT1 Connector > MCE1/T1 Logical Lines
Default: 1600 bytes
Options: 3 to 4608 bytes
Function: Specifies the transmit/receive buffer size (MTU) to configure the largest frame
that the router can transmit or receive across this MCE1 port. The router
discards frames larger than this value.
Instructions: Enter a value in the range 3 to 4608 bytes.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.55