Site Manager WAN Line Services Parameters
117021-A Rev. A A-43
Parameter: BofL
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: Enable
Options: Enable
| Disable
Function: Enables the transmission of proprietary BofL messages over a point-to-point
connection between the local router and a remote peer.
Instructions: Set to Enable or Disable, depending on whether you want to transmit BofL
messages over this synchronous interface. If you enable BofL locally, the
remote peer must also be configured to enable BofL.
We recommend that you enable BofL for point-to-point connections between
Bay Networks peers. However, if such a connection is accomplished through a
wide area transport service such as Frame Relay, X.25, or SMDS, you must
disable BofL.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.7
Parameter: BofL Timeout
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: 5 seconds
Options: 1 to 60 seconds
Function: Specifies the time between transmissions of BofL messages from this
synchronous interface. Timeout will occur if five periods elapse without both a
successful frame transmission and a successful reception. When timeout occurs,
the router disables and reenables the synchronous line. For example, if you set
this parameter to 5 seconds, the interface must successfully transmit and receive
a frame within 25 seconds. Timeout occurs in 25 seconds.
This parameter is valid only if you set BofL to Enable.
Instructions: Either accept the default, 5 seconds, or specify a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.8