Configuring WAN Line Services
2-6 117021-A Rev. A
Enabling or Disabling Remote Address Filtering
Set the Promiscuous parameter to specify whether the interface filters packets for
addresses other than its own local address, or whether address filtering is based on
the both the local and remote addresses.
With this parameter set to Enable, the interface receives all frames. By default,
address filtering is disabled: the interface receives only frames destined for its
local address. Enable or disable local and remote (promiscuous) address filtering
on the interface.
Configuring Clocking Signals
By default, the synchronous interface operates with an External clock source at
64102 b/s. You can configure the source and speed of synchronous timing signals:
Setting the Clock Source
Setting the Internal Clock Speed
Setting the External Clock Speed
Setting the Clock Source
The Clock Source parameter specifies whether the origin of the synchronous
timing signals are supplied by the router (Internal) or supplied by a network
device (External).
With this parameter set to Internal, the router supplies the required timing signals.
If you set the clock to Internal, set the internal clock speed as described in the next
section.
With this parameter set to External (the default), an external network device
supplies the required timing signals. In most cases, this parameter should be set to
External. See the “Setting the External Clock Speed” section.
Set the clock source to Internal or External for the interface.
Site Manager: Promiscuous parameter: page A-42
Site Manager: Clock Source parameter: page A-43