Site Manager WAN Line Services Parameters
117021-A Rev. A A-49
Parameter: Extended Address
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: Disable
Options: Enable
| Disable
Function: Enables or disables testing of the address length. When you set this parameter to
Enable, the router tests the first bit of the address to determine the length of the
address, in octets.
Instructions: Accept the default, or select Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.22
Parameter: Extended Control (S and I frames)
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: Disable
Options: Enable
| Disable
Function: Allows the control fields of all S- and I- frames to become two octets in length
instead of one. Numbering of all I-frames becomes Modulo 128 instead of
Modulo 8.
Instructions: Accept the default or select Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.24
Parameter: Transmit Window Size
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: 1 frame
Options: 1 to 7 frames
Function: Controls the number of I-frames that can be transmitted without
acknowledgment.
Instructions: Either accept the default value, or enter a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.27