Customizing Signaling
303514-A Rev. 00
4-17
connect-tx-timer T313 4 1 to 24 Specifies the Connect Sent timer value (in
seconds). This timer be
ins when the circuit sends
a CONNECT messa
e to the network.
The Connect Sent timer stops when the circuit
receives a CONNECT ACKNOWLEDGE messa
e
from the network (indicatin
the completion of the
ATM connection for that interface).
If the timer expires before the circuit receives a
CONNECT ACKNOWLEDGE messa
e, the circuit
clears the connection.
restart-request-tx-
interface-timer
T316
120 1 to 720 Specifies the Restart Request Sent on Interface
timer value (in seconds). This timer be
ins when
the circuit sends a RESTART messa
e to the
network. The circuit uses the RESTART messa
e to
return all VCs on the interface to the idle condition.
The Restart Request Sent on Interface timer stops
when the circuit receives a RESTART
ACKNOWLEDGE messa
e from the network.
If the timer expires before the circuit receives a
RESTART ACKNOWLEDGE messa
e, the circuit
can retransmit the RESTART messa
e (see
“Settin
the Number of Allowable Restart
Messa
es” on pa
e4-22). If the circuit still does not
receive a response, the circuit enters the null state
until the appropriate maintenance action is taken.
(continued)
Table 4-1. Signaling Timer Descriptions