Avaya Configuring ATM Services Bedienungsanleitung Seite 330

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 428
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 329
Configuring ATM Services
A-36
303514-A Rev. 00
Parameter: Max Number of SVC Applications
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 20
Options: 1 to 32767
Function: Specifies the maximum number of SVC applications allowed for this circuit.
The number of SVC applications corresponds to the number of LAN emulation
or IP (RFC 1577) clients allowed for the circuit.
Instructions: Accept the default, 20, or enter a value from 1 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.6
Parameter: Max Point to Point Connections
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 1000
Options: 0 to 32767
Function: Specifies the maximum number of simultaneous point-to-point connections
allowed for this circuit.
Instructions: Accept the default, 1000, or enter a value from 0 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.7
Parameter: Max Point to Multipoint Connections
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 40
Options: 0 to 32767
Function: Specifies the maximum number of simultaneous point-to-multipoint
connections allowed for this circuit.
Instructions: Accept the default, 40, or enter a value from 0 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.8
Seitenansicht 329
1 2 ... 325 326 327 328 329 330 331 332 333 334 335 ... 427 428

Kommentare zu diesen Handbüchern

Keine Kommentare