Configuring ATM Services
B-12
303514-A Rev. 00
show dsx3 current
The
show dsx3 current
command displays line, Pbit, Cbit, and Plcp statistics for the
DSX3 circuits in the configuration.
The output includes the following information:
Slot/<Module>/Conn The slot, module, and connector number of the DSX3 circuit.
Circuit Name of the circuit associated with this line.
Sec into Interval The number of seconds into the current 15-minute interval.
# of Intervals The number of complete 15-minute intervals.
Line Codin
The line codin
on this circuit. The line codin
options are:
•B3ZS
• HDB3
Line Type Status The line status of the interface. The possible status values are:
•
NoAlarm
- no alarm present
•
RRAI
- receivin
yellow remote alarm indication
•
TRAI -
transmittin
yellow remote alarm indication
•
RAIS
- receivin
Alarm Indications Si
nal (AIS) failure state
•
TAIS
- transmittin
AIS failure state
•
LOF
- receivin
Loss of Frame (LOF) failure state
•
LOS
- receivin
Loss of Si
nal (LOS) failure state
•
Loopback
- loopin
the received si
nal
•
TestCode
- receivin
a test pattern
•
LowSignal
- low si
nal
Line Stats
Circuit Name of the circuit associated with this line.
Interval The current interval.
LESs The number of line errored seconds (LESs) in the current interval.
An LES is a second in which one or more codin
violations occurred
or one or more LOS defects were detected.
SEFSs The number of severely errored framin
seconds (SEFSs) in the
current interval. An SEFS is a second with one or more OOF errors
or an AIS defect.
UASs The number of unavailable seconds (UASs) in the current interval.
LCVs The number of line codin
violations (LCVs) in the current interval.
A line codin
violation is a count of both bipolar violations (BPVs)
and excessive zero (EXZ) error events.