Configuring Bridging Services
2-40 114060 Rev. A
Source Routing Interface Parameter Descriptions
Use these parameter descriptions as a guide when you configure the parameters in
the SR Interface List window (refer to refer to Figure
2-19). (Refer to Chapter 3
for descriptions of the NetBIOS parameters on this screen.)
Parameter: Enable
Default: Enable
Options: Enable
| Disable
Function: Enables or disables source routing over this circuit.
Instructions: Set this parameter to Enable to enable source routing over this circuit.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.1.2.2.1.2
Parameter: Max number of RDs
Default: 7
Range: 1 to 7
Function: Specifies the maximum number of route descriptors allowed in incoming
explorer frames. Any explorer frames received that contain more route
descriptors than specified here are dropped.
Instructions: Accept the default unless you want to limit the number of networks this
router can reach.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.1.2.2.1.5