System Administration
308657-14.00 Rev 00
7-23
The type of router (single-slot or multislot)
Based on these variables, the router system or slot performs a restart, a
warm-boot, or cold-boot operation. Table 7-4
describes the various responses the
router can have to different
reset commands.
Table 7-4. Router Reset Commands and Respones
You issued a reset command from a Technician Interface session (console or Telnet)
on one slot, and the target
<slot_no.>
you specified was:
(None)
The same slot on which the
session is running
A slot other than the slot
on which the session is
running
Command-
>
reset reset
<slot_no.>
reset
<slot_no.>
Router
AN
ANH
ARN
(single-slot)
Warm-boot slot 1:
No diagnostics
Load new image on slot 1
Initialize new image on
slot 1
Retain log info
Warm-boot slot 1:
No diagnostics
Load new image on slot 1
Initialize new image on
slot 1
Retain log info
N/A
BLN
BLN-2
BCN
(multislot)
Warm-boot all slots:
No diagnostics
Load new image
Initialize new image
Retain log info on all slots
Warm-boot the designated
slot:
No diagnostics
Load new image on
designated slot
Initialize new image on
designated slot
Retain log info on
designated slot
Warm-boot the designated
slot:
No diagnostics
Load new image on the
designated slot
Initialize new image on
the designated slot
Retain log info on the
designated slot
Note:
If you reset the slot in which the Technician Interface is running, the
Technician Interface resets with the next available slot on a multislot system,
or with the same slot on a single-slot system.