Avaya Using Technician Interface Software Bedienungsanleitung Seite 328

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 344
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 327
Using Technician Interface Software
C-40
308657-14.00 Rev 00
Parameter: Severity Mask
Attribute Name: wfSyslogEntFltrSevMask
Attribute Number: 9
Default: None
Options: w (warning)
i (information)
t (trace)
f (fault)
d (debug)
Use individually (such as
f
or
d
) or combined (such as
fwitd
).
Function: Identifies the severity levels of events you want to forward. Syslog uses
this severity mask as filtering criteria only if you specify the wildcard
event number range (0 to 255) as the values for
wfSyslogEntFltrLogEvtLowBnd and wfSyslogEntFltrLogEvtUppBnd.
Syslog looks only for events that have the severity levels you specify.
Instructions: If you specify a range of event numbers (using the Log Evt Lower Bound
and Log Evt Upper Bound parameters), Syslog ignores the Severity Mask
parameter.
If you do not specify a range of event numbers, Syslog applies the value
of the Severity Mask attribute to the current filter. Enter the severity level
identifiers of event messages you want to forward to the remote host
associated with this filter. Use the first letter of each event severity level
you want to include:
f - fault
w - warning
i - information
t - trace
d- debug
Enter lowercase letters only. Do not separate the letters with commas or
spaces.
Command:
set wfSyslogEntFltrEntry.wfSyslogEntFltrSevMask.
<host_IP_address>
.
<entity_code>
.
<filter_index>
<witfd>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.9
Seitenansicht 327
1 2 ... 323 324 325 326 327 328 329 330 331 332 333 ... 343 344

Kommentare zu diesen Handbüchern

Keine Kommentare