Chapter 4 Configuring the R2MFC MBM 47
R2MFC Media Bay Module Installation and Configuration Guide
The custom profile remains in EEPROM, even if different country codes are selected with
the DIP switches, and is available again when the “custom profile” DIP switch setting is
selected. The first configuration change by the CLI overwrites the existing custom profile
as described above.
4 Set the Config DIP switches to custom profile. The new custom profile is used upon restart.
See Figure 16 for the custom profile DIP switch setting.
Figure 16 Custom profile DIP switch setting
PRI side (Internal Link) configurable parameters
The R2MFC MBM is recognized by the BCM as a Euro-ISDN PRI line. The configuration for the
PRI side (internal link) of the link is performed on the BCM through the Unified Manager. Refer
to the Installation and Maintenance guide for the host system for complete information on the
parameters that can be configured through the BCM. PRI side, internal link, and operational
parameters for E1framing and signaling are listed below:
E1 Framing
The list of E1 framing parameters are listed in Table 3.
Note: Only one custom profile exists in EEPROM, so the SaveCfg
command overwrites the previous custom profile saved to the EEPROM.
Table 3 E1 framing default parameters
Parameter Operational Value
Frame format alternate frame
PCM coding A-law
Common Channel Signaling TS16
123456