92 Config DIP switch settings and definitions
N0027684 01
Brazil Config 1
E1 physical characteristics
Connector type: BNC
Line coding: HDB3
E1 framing
Frame mode: Alternate
Register signaling
Regret option: ON
End of dialing (Incoming): 4
End of dialing (Outgoing): 4
R2 line signaling
Brazil Config 1 R2 signals are according to CCITT standard. See Table 32 for the Brazil Config 1
R2 signal definitions.
Note: CD bits are not used. They are set to 01 in transmit direction, and are ignored in receive direction.
MFC Register Signaling
MFC signal definitions depends on the stage and the direction of the call; there are four tables of
15 signals each: the first stage uses I signals forward and A signals backward, and the second stage
uses II signals forward and B signals backward. The meaning of the signals can also be different
when being transmitted or received. Meanings of the MFC signals are configurable. MFC signal
tables are part of the country-specific parameters.
Table 32 Brazil Config 1 R2 A/B signals
Forward Backward
SignalABSignalAB
Idle 1 0 Idle 1 0
Seize 0 0 Seize acknowledge 1 1
Clear forward 1 0 Answer 0 1
Clear back 1 1